-40%

Dayton Model 1TDR3 PSC Draft Fan Blower, 115 Volt, Replaces 4C447, CFM 273

$ 58.07

Availability: 49 in stock
  • Restocking Fee: No
  • Motor Type: Permanent Split Capacitor
  • Power Frequency: 60 hz
  • Model: 1TDR3
  • Axial Fan Bearing Type: Ball Bearing
  • Return shipping will be paid by: Buyer
  • Ventilation Type: Supply Only
  • Condition: New
  • Type: Centrifugal
  • Brand: Dayton
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Voltage: 115 V
  • Maximum Air Flow: 251-350 CFM
  • Power Phase: 1 Phase
  • MPN: FN1TDR3
  • Item must be returned within: 30 Days

    Description

    Product Description
    Dynamically balanced, the
    Dayton 1TDR3 Blower mounts in any position and operates with minimal noise and vibration to maintain CFM at higher static pressures.
    Dayton Blowers 1TDR3 PSC Draft Fan Blower, 115 Volt, Replaces 4C447
    Performance Data
    CFM @ 0.000-In SP: 273
    115 Volts, 50-60 Hz, 1 Phase
    Max Ambient Temp: 104 Deg F
    Full Load Amps: 0.77
    Motor RPM: 1640
    Dimensions:
    Overall height 9 7/8'', overall width 7 11/16'', overall depth 8 7/8''
    Technical Specs
    Item OEM Blower
    Outlet Shape Rectangular
    With/Without Flange With Flange
    Wheel Dia. 5-1/8"
    Wheel Width 1-7/8"
    CFM @ 0.000-In. SP 273
    CFM @ 0.100-In. SP 245
    CFM @ 0.200-In. SP 230
    CFM @ 0.300-In. SP 210
    CFM @ 0.400-In. SP 183
    CFM @ 0.500-In. SP 135
    Voltage 115
    Hz 50/60
    Phase 1
    Full Load Amps 0.77
    RPM 1640
    Bearing Type BALL
    Motor Type Permanent Split Capacitor
    Motor Enclosure Open
    Motor Insulation Class B
    Thermal Protection Auto
    Lead Length 13"
    Conduit Box Yes
    Max. Ambient Temp. 104 Degrees F
    Max. Inlet Temp. 104 Degrees F
    Inlet Dia. 4-5/8"
    Outlet Height 3-5/8"
    Outlet Width 4-1/8"
    Overall Height 9-7/8"
    Overall Width 7-11/16"
    Overall Depth 8-7/8"
    Wheel Type Forward Curve
    Drive Type Direct
    Mounting Position All Position
    Housing Finish Enamel
    Housing Material Rolled Steel
    Housing Color Gray
    Agency Compliance UL Recognized US and Canada (E47479), CE
    Replaces 4C447
    Includes Discharge Mounting Flange
    This is a Direct replacement Draft Fan Blower
    Used for many other applications. PSC Blower, Forward Curve, Direct Drive, Wheel Dia 3 15/16 In, CFM @ 0.000-In SP 75, Voltage 115, 60 Hz, Single Phase, Full Load Amps 0.45, RPM 3016, Max Inlet Temp 104 Deg F, Overall Height 9 3/4 In, Overall Width 7.5 In, Overall Depth 8.8 In, Includes Discharge Mounting Flange.
    12 to 75 CFM PSC and Shaded Pole Blowers, Round Outlet
    Dynamically balanced blowers provide smooth and quiet operation.
    Noise and vibration are held to a minimum to maintain CFM at higher static pressures.
    Motors have cast aluminum end shields for greater heat dissipation and protection, resulting in less downtime and longer service life.
    UL and C-UL Recognized (E47479).
    Direct replacements for many OEM blowers with same physical footprint
    All-position mounting
    Min./max. operating temp. range: -20 Degree to 104 DegreeF
    Max. inlet and ambient temp.: 104 DegreeF
    Motor enclosure: open
    Reference: 4C447, 7063-3277 Fasco B45227
    Dayton Catalog # 1TDR3
    Features
    Dynamically balanced blowers provide smooth and quiet operation.
    Noise and vibration are held to a minimum to maintain CFM at higher static pressures. Motors have cast aluminum end shields for greater heat dissipation and protection, resulting in less downtime and longer service life.
    UL and C-UL Recognized (E47479), except No. 2C646 is not UL or C-UL Recognized, and No. 2C647 is UL Recognized (E22286) and CSA Certified (LR12645).
    Direct replacements for many OEM blowers with same physical footprint
    All-position mounting
    Min./max. operating temp. range: -20 Degree to 104 DegreeF
    Max. inlet and ambient temp.: 104 DegreeF
    Motor enclosure: open
    Replaces the Dayton 4C447